Whirlpool RH3736XL Manuel d'utilisation

Page 8

Advertising
background image

8

Wall Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:

1. Make 2 lines by measuring from floor 65

⁷⁄₈" (167.3 cm) and

62

³⁄₈" (158.4 cm) or ¹⁄₈" (3.2 mm) and 3⁵⁄₈" (9.2 cm) down from

underside of cabinet and mark on the centerline on the back
wall.

2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline

on the wall.

3. Use saber or keyhole saw to cut a rectangular opening in the

wall for the vent.

Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System

Roof Venting

To make a 7

¹⁄₄" (18.4 cm) circle on the underside of the cabinet

top and bottom:

1. Mark a centerline on the underside of the cabinet bottom.

2. Mark a line

5" (12.7 cm) from the back wall on the underside

of the top of cabinet.

3. Draw a circle using a compass or 7

¹⁄₄" (18.4 cm) circle

template.

4. Use saber or keyhole saw to cut a 7

¹⁄₄" (18.4 cm) diameter

opening.

5. Repeat steps 1-4 for the underside of the top of the cabinet.

Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 7" (17.8 cm) Round Vent Transition

Roof Venting

To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:

1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall

on the centerline of the underside of cabinet.

2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline

on the underside of cabinet.

3. Use saber or keyhole saw to cut a rectangular opening for

vent.

To make a 7

¹⁄₄" (18.4 cm) circle on the underside of the cabinet

top:

1. Mark a centerline on the underside of the top of cabinet.

2. Mark a line

5" (12.7 cm) from the back wall on the underside

of the top of cabinet.

3. Draw a circle using a compass or 7

¹⁄₄" (18.4 cm) circle

template.

4. Use saber or keyhole saw to cut a 7

¹⁄₄" (18.4 cm) diameter

opening.

Install Vent System

1. Install vent through the vent opening in upper cabinet or wall.

Complete venting system according to the selected venting
method. See “Venting Requirements” section.

2. Use caulking to seal exterior wall or roof opening around the

cap.

¹⁄₈

"

3 ⁵⁄₈

"

Cabinet

front

5

¹⁄₄

"

(3.2 mm)

(9.2 cm)

(13.3 cm)

Centerline

7

¹

/

" (18.4 cm) diam.

cabinet cutouts

*From wall, not

cabinet frame

*5"

(12.7 cm)

5

¹

/

"

(13.3 cm)

5

¹

/

"

(13.3 cm)

*5

¹

/

"

(14 cm)

*From wall, not cabinet frame

*1

¹

/

" (3.8 cm)

7

¹

/

" (18.4 cm) diam.

Cabinet

cutouts

*From wall, not

cabinet frame

*5"

(12.7 cm)

Advertising