Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.

If the house has aluminum wiring follow the procedure below:

1. Connect a section of solid copper wire to the pigtail

leads.

2. Connect the aluminum wiring to the added section of

copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the hood.

Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.

Maximum Recommended Length

= 50 ft (15.2 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of 7" (17.8 cm) system

= 13.0 ft (3.9 m)

Vent Piece

7" (17.8 cm) Round

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

90° elbow

5.0 ft
(1.5 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

flat elbow

12.0 ft
(3.7 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

wall cap

0.0 ft
(0.0 m)

Maximum Recommended Length

= 35 ft (10.7 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

1 - wall cap

= 0.0 ft (0.0 m)

Length of 3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

system

= 13.0 ft (3.9 m)

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

Wall cap

3

¹⁄₄

" x 10"

(8.3 x 25.4 cm)

elbow

2 ft

(0.6 m)

6 ft (1.8 m)