Inserting sequencer data (create), Erasing sequencer data (erase), The beginning of the song (p. 156) – Roland Piano Manuel d'utilisation

Page 156: 156 editing songs

Advertising
background image

156

Editing Songs

4.

Turn the VALUE dial or press [INC]/[DEC] to edit the value.

If you want to add data between “F0:” and “:F7,” move the
cursor to that location and press [5 (Insert)]. A value of “00” will
be inserted. Change this to the desired value.

To delete data, move the cursor to the relevant location and
press [6 (Delete)].

5.

When you are finished editing, press [8 (OK)] to finalize the

values of the system exclusive message.

• If you decide to discard the changes you made to the system

exclusive message and return to the Microscope window, press
[EXIT].

• In the case of a Roland type IV system exclusive message, the

checksum can be calculated automatically when you finalize the
values. If you do not want to calculate the checksum
automatically, press [1 (Checksum)] to remove the check mark
(✔) from “Auto Calculate Checksum.”

Inserting Sequencer Data (Create)

You can insert new sequencer data into a desired location of a phrase
track or pattern.

For details on the sequencer data that can be inserted, refer to

“Sequencer Data Handled by a Phrase Track/Pattern”

(p.

154).

1.

Access the Microscope window for the track or pattern into

which you want to insert sequencer data (p. 153).

2.

Press

or

to move the cursor to the location at which

you want to insert sequencer data.

If the location at which you want to insert sequencer data is not
shown in the display, move the cursor to the appropriate
location (measure-beat-clock), and then specify the insert
location for the sequencer data.

3.

Press [1 (Create)].

The Create Event window appears.

fig.11-33_50

4.

Press

or

to select the sequencer data that will be

inserted.

If you want to insert a system exclusive message, select “Sys.Excl
(Default).” However, if you want to insert a General MIDI
System On message or General MIDI 2 System On message in
order to initialize the sound generator to the GM default state,
select “Sys.Excl (GM ON)” or “Sys.Excl (GM2 ON),” and to exit
the GM state select “Sys.Excl (GM OFF).”

5.

Press [8 (Execute)] to insert the sequencer data.

Once the sequencer data has been inserted, you’ll be returned to
the Microscope window.

6.

The sequencer data that was inserted will have the default

parameter values, so edit them as necessary.

If you are not satisfied with the results of executing this
operation, press [MENU], and from the Menu window that
appears, select “Undo Micro Edit” to return to the state prior to
execution (Undo).

Erasing Sequencer Data (Erase)

If desired, you can erase just an individual event of sequencer data.
You can also use the same operation to erase individual items of data
from the tempo track or beat track.

It is not possible to erase the tempo change located at the
beginning of the tempo track, the beat change and key signature
located at the beginning of the beat track, or the pattern beat.

1.

Access the Microscope window for the track or pattern from

which you want to erase sequencer data (p. 153).

2.

Press

or

to move the cursor to the sequencer data

that you want to erase.

To erase a multiple consecutive data, hold down [SHIFT] and

press

to select the sequencer data.

3.

Press [2 (Erase)] to erase the sequencer data.

If you are not satisfied with the results of executing this
operation, press [MENU], and from the Menu window that
appears, select “Undo Micro Edit” to return to the state prior to
execution (Undo).

Advertising