The underlining indicates the factory setting.

400

STILL TIMER

0000
0001
0002
0003
0004
0005
0006
0007
0008

0.5s

5s

10s
20s
30s
40s
50s

1min
2min

This selects the time taken for the unit to be set to the tape
protection mode when it has been left standing in the STOP or
search STILL (JOG, VAR or SHTL) mode.
(Units: s = second, min = minute)

403

STOP PROTECT

0000
0001

STEP

HALF

This selects the tape protection mode operation when the unit has
been left standing in the STOP mode.
0: Step FWD
1: Half loading
<Note>
When step FWD has been set, the unit is automatically transferred
to the half loading mode when it has been left standing for a total
of 30 minutes in the STOP mode.

401

SRC PROTECT

0000
0001

STEP

HALF

This selects the tape protection mode operation when the unit has
been left standing in the STILL mode.
0: Step (or step FWD in STILL mode).
1: Half loading
<Note>
When step FWD has been set, the unit is automatically transferred
to the half loading mode when it has been left standing for a total
of 30 minutes in the STILL mode.

402

DRUM STDBY

0000
0001

OFF

ON

This selects the drum operation in the standby OFF mode.
0: The drum is stopped.
1: The drum is rotated.

[

[

[

[

[

[

[

[