Panasonic WJ-HD500A Manuel d'utilisation

Page 69

Advertising
background image

69

Parity Check

This item lets you set the parity bit for RS-485 communica-
tion.

1. Move the cursor to the PARITY CHECK parameter by

pressing the D or C button.

2. Select NONE, EVEN or ODD for parity check by press-

ing the + or - button.

The factory default setting is NONE.

Stop Bit

This item lets you set the number of stop bits for RS-485
communication.

1. Move the cursor to the STOP BIT parameter by press-

ing the D or C button.

2. Select either 1 or 2 for the number of stop bits by press-

ing the + or - button.

The factory default setting is 1 bit.

Wait Time

This item lets you set the waiting time in milli-seconds (ms)
to retry after confirming that no data is received from the
controller for RS-485 communication.

1. Move the cursor to the WAIT TIME parameter by press-

ing the D or C button.

2. Select OFF, 100, 200, 400, or 1 000 ms for the wait time

by pressing the + or - button.
When no transmission is needed, select OFF.

The factory default setting is OFF (no retry).

Alarm Data

This item lets you enable or disable notification of the alarm
data received to the controller (Unit Number 1).

1. Move the cursor to the ALARM DATA parameter by

pressing the D or C button.

2. Select the desired mode by pressing the + or - but-

ton.

OFF:

Select this parameter if the system controller is

not connected to the system.

0S:

Each time an alarm is received, it is transmitted to

the system controller.

1S:

The received alarm is stored for 1 second, and that

data is sent to the system controller.

5S:

The received alarm is stored for 5 seconds, and

that data is sent to the system controller.

The factory default setting is 1S.

Input (Camera) Number Setup

This item lets you assign numbers for the input from the
system cameras for RS-485 communication.

1. Move the cursor to CAMERA NUMBER SETUP by

pressing the D or C button, then press the

SET

button.

The CAMERA NUMBER SETUP table shown below
appears on the monitor screen.

2. Move the cursor to the input (CAM-PORT) parameter to

edit by pressing the D, C, A or B button, then select
a camera number by pressing the + or - button.

---:

No assignment.

001 - 128:

Assigns the selected number.

Note:

Make sure not to assign the same number to

more than one system camera for RS-485 communi-
cation.

3. Repeat the above procedure to edit other input para-

meters.

4. After completing the settings, press the

SETUP/ESC

button to return to the previous setup menu.

8-1-1 CAMERA NUMBER SETUP

CAM-PORT CAM NO. CAM-PORT CAM NO.
1 001 9 009
2 002 10 010
3 003 11 011
4 004 12 012
5 005 13 013
6 006 14 014
7 007 15 015
8 008 16 016

Advertising