Communication setup, Data setup – Panasonic WJ-HD500A Manuel d'utilisation

Page 68

Advertising
background image

68

The procedures described below let you set the parame-
ters for the Disk Recorder to communicate with external
devices.

1. Move the cursor to COMMUNICATION SETUP in the

WJ-HD500 SETUP menu by pressing the C or D but-
ton, then press the

SET

button.

The COMMUNICATION SETUP menu shown below
appears on the monitor screen.

2. Select an item or item parameter in the menu by press-

ing the D or C button.

3. To return to the previous WJ-HD500 SETUP menu,

press the

SETUP/ESC

button.

PS

Data Setup

These items let you set the parameters for communication
between the System Controllers and the Disk Recorders
when the system is controlled with the PS

Data mode

(Panasonic Security Data).

1. Move the cursor to PS

Data SETUP in the COMMUNI-

CATION SETUP menu by pressing the C or D button,
then press the

SET

button.

The PS

Data SETUP menu shown below appears on

the monitor screen.

2. Select an item or item parameter in the menu by press-

ing the D or C button.

3. To return to the previous setup menu, press the

SETUP/ESC

button.

Unit Address Setting

This item lets you set the unit address of the Disk Recorder
in the system for RS-485 communication.

1. Move the cursor to the UNIT ADDRESS parameter by

pressing the D or C button.

2. Select the unit address number to be used for RS-485

communication by pressing the + or - button.
Select a parameter value between 001 and 099.

The factory default setting is 001.

Baud Rate

This item lets you set the transmission speed for RS-485
communication.

1. Move the cursor to the BAUD RATE parameter by

pressing the D or C button.

2. Select the desired transmission speed shown below by

pressing the + or - button.

The factory default setting is 9 600 bps.

Data Bit

This item lets you set the number of data bits for RS-485
communication.
The factory default setting is 8 bits and fixed.

8 COMMUNICATION SETUP

PS•Data SETUP
RS232C SETUP

NETWORK SETUP
IP ADDRESS 192.168.000.010
NETMASK 255.255.255.000
GATEWAY 192.168.000.001

8-1 PS•Data SETUP

UNIT ADDRESS 001
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
ALARM DATA 1S

CAMERA NUMBER SETUP

2 400

4 800

9 600

19 200

38 400

COMMUNICATION SETUP