106 – english, Basic format, Control commands – Panasonic PT-DW100U Manuel d'utilisation

Page 106: Using the serial terminals (continued)

Advertising
background image

106

ENGLISH

Using the serial terminals (continued)

Basic format

Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this
order. Add parameters according to the details of control.

STX

C1

C2

C3

:

P1

P2

Pn

ETX

A D

I 1 I 2

;

Start

(1 byte)

(2 bytes)

Two ID

characters

(2 bytes)

ZZ, 1 to 64 and 0A to 0Z

Semicolon

(1 byte)

ID designate

3 command

characters

(3 bytes)

Colon

(1 byte)

Parameter

(undefined length)

End

(1 byte)

Attention

No command can be sent or received for 10 to 60 seconds after the lamp starts lighting. Try sending any

command after that period has elapsed.

When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the

response from the projector before sending the next command. When sending commands without parameters,
a colon (:) is not necessary.

Note

When the wrong command is sent, the “ER401” or “ER402” status is sent from the projector to the personal

computer.

Projector ID supported on the RS-232C interface is ZZ (ALL) and a group of 1 to 64 and 0A to 0Z.

The “STX” character code is 02 and the “ETX” character code is 03.

If a command is sent with a projector ID specified, the projector will return answer back only in the following

cases:
If it coincides with the projector ID
If the ID specification is ALL and responding (ID ALL) is on
If the ID specification is Group and responding (ID Group) is on

Control commands

When controlling the projector from a computer, the following commands are available:

Command Function of command

Remarks

PON

Power “ON”

In standby mode, commands other than “PON” are invalid.

While the lamp is ON and being controlled, a “PON” command will not be

accepted.

POF

Power “OFF”

IIS

Switch input modes

Parameter
VID = VIDEO

SVD = S-VIDEO DVI = DVI-D

RG1 = RGB1

RG2 = RGB2

AUX = AUX

QSL

Query for active lamp

mode

Parameter
0 = QUAD, 1 = L1/L4, 2 = L2/L3, 3 = DUAL, 4 = L1/L2/L3, 5 = L1/L2/L4,
6 = L1/L3/L4, 7 = L2/L3/L4, 8 = TRIPLE, 9 = L1, 10 = L2, 11 = L3, 12 = L4,
13 = SINGLE

LPM

Active lamp mode

Parameter
0 = QUAD, 1 = L1/L4, 2 = L2/L3, 3 = DUAL, 4 = L1/L2/L3, 5 = L1/L2/L4,
6 = L1/L3/L4, 7 = L2/L3/L4, 8 = TRIPLE, 9 = L1, 10 = L2, 11 = L3, 12 = L4,
13 = SINGLE

Note

If you need a detailed command list, please contact your dealer.