RS-232C

$

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QLP:n [ETX]

Parameter
n = 0—3
Up to the last 4 sets of data are
designated by this parameter with 0
serving as the latest data.

[STX] LPLnn:data1:data2 [ETX]

Parameter
nn = 00—99: Alarm number

data1 = yyyymmdd

yyyy = 2000—2099: Gregorian

calendar

mm:

01—12: Month

dd =

01—31: Day

data2 = hhmmss

hh = 00—23: Hours (24-hour system)
mm = 00—59: Minutes
ss =

00—59: Seconds

Queries the POWER LOSS MEMORY data.

[STX] QLZ [ETX]

[STX] LBZm [ETX]

Parameter
m = N: Buzzer ON

F: Buzzer OFF

Queries the setting of the buzzer operation during alarm
recording and/or sensor recording.

[STX] QMA [ETX]

[STX] LMAm [ETX]

Parameter
m = F: Search mode OFF

M: Memory stop mode
A: Alarm search mode

Queries the search mode.

[STX] QLT [ETX]

[STX] LTMm [ETX]

Parameter
t =

0: 3-hour recording
1: 9-hour recording
2: 12-hour recording
3: 18-hour recording
4: 24-hour recording
5: 48-hour recording
6: 72-hour recording
7: 96-hour recording
8: 120-hour recording
9: 180-hour recording
A: 240-hour recording
B: 360-hour recording
C: 480-hour recording
D: 960-hour recording

Queries the recording/playback time mode setting.