Rs-232c, Query control commands – Panasonic AG-DTL1 Manuel d'utilisation

Page 90

Advertising
background image

90

RS-232C

$

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QMS [ETX]

[STX] LMSm [ETX]

Parameter
m = 0: 1 second

1: 1.5 seconds
2: 2 seconds
3: 2.5 seconds
4: 3 seconds
5: 4 seconds
6: 5 seconds
7: 10 seconds

Queries the timing at which to switch the video signals
which are supplied from the camera and which are to be
output from the rear panel VIDEO OUT connector.

[STX] QLD:n [ETX]

Parameter
n = 0—7
Up to the last 8 sets of data are
designated by this parameter with 0
serving as the latest data.

[STX] LANnn:data1:data2 [ETX]

Parameter
nn = 00—99: Alarm number

data1 = yyyymmdd

yyyy = 2000—2099: Gregorian

calendar

mm:

01—12: Month

dd =

01—31: Day

data2 = hhmmss

hh = 00—23: Hours (24-hour system)
mm = 00—59: Minutes
ss =

00—59: Seconds

Queries the ALARM RECALL data.

[STX] QLE [ETX]

[STX] LRIm [ETX]

Parameter
m = A: Alarm signal input is

acknowledged.

F: Alarm signal input is ignored.

Queries the setting for the alarm recording and/or sensor
recording to be performed if an alarm signal has been input
while repeat recording is underway or while the tape is
being rewound.

[STX] QLH [ETX]

[STX] LHRhhhh [ETX]

Parameter
hhhh = 0000—9999
The cumulative drum rotation time in
hours is returned as a 4-digit figure.

Queries the current value of the hour meter.

[STX] QLM [ETX]

[STX] LRMm [ETX]

Parameter
m = E: External timer recording

I:

Internal timer recording

N: Regular recording

Queries the timer recording mode setting.

Advertising