RS-232C

$

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QAL [ETX]

[STX] ALV0 [ETX]

Queries the address level. It supports only address level 0
in the MIS standards.

[STX] QAM:m [ETX]

Parameter
m = M: MODE

Queries the recording
mode when an alarm signal
has been input.

F: FIELD/FRAME

Queries the recording
mode in which alarm
recording and/or sensor
recording is to be
performed.

P: PICTRE QUALITY

Queries the picture quality
with which alarm recording
and/or sensor recording is
to be performed.

T: ALARM 1/2 REC-TYPE

Queries the recording type
to be used when an alarm
signal has been input to
ALARM IN 1 or 2.

[STX] LDmdata [ETX]

Parameter
m = M: MODE

m = F: FIELD/FRAME

m = P: PICTRE QUALITY

m = T: ALARM 1/2 REC-TYPE

data =m:n

m = 0—7: ALARM IN 1 recording

type

n = 0—7: ALARM IN 2 recording

type

data =

H: HIGH

Recording at a high picture
quality

N: NORMAL

Recording at the standard
picture quality

F: NO CHANGE

Recording at the picture
quality currently set

data =

I: Field recording
R: Frame recording

data =

F: OFF

Alarm signal input is ignored.

M: ALARM/SENSOR

Alarm recording and/or sensor
recording is performed.

A: ALARM

Alarm recording is performed.

S: SENSOR

Sensor recording is
performed.

Queries the alarm recording and sensor recording settings.

[STX] QBM [ETX]

[STX] LBMm [ETX]

Parameter
m = N: ON

The black burst signal is
output.

F: OFF

The black burst signal is not
output.

Queries the processing of the black burst signal when the
video signals to be output from the video signal output
connector are switched.

Advertising