Indication of lamp monitor – Panasonic PT-D4000U Manuel d'utilisation

Page 50

Advertising
background image

50

Indication of lamp monitor

This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal
internal temperature. These lamps flash or light up to indicate a problem.
Turn the power off and follow the steps below.

Temperature monitor (TEMP)

Lamp 1 monitor (LAMP 1)

Lamp 2 monitor (LAMP 2)

(Power indicator)

• To solve any problems that the TEMP and LAMP monitor show, first turn the power off by

following the steps on pages 22, 23.

• If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your dealer.
• If the power indicator flashes red (once), the lamp unit cover is not properly fitted. Check the fitting

of the lamp unit cover.

Attention

Name of monitor

lamp

Lamp

indication

Information

High temperature
inside. (WARNING)

• Check if the

ventilation port is
blocked.

• Is the room air

temperature too high?

• Is the air filter clogged

with dust?

Warm-up status

• Did you turn on the

power when the
ambient temperature
was low
(approx. 0 °C)?

Checkpoint

• Wait about five minutes in the

current status.

• Install the unit in a location

having an ambient temperature
from 0 °C to 45 °C.

• Remove the object that is

blocking the ventilation port.

• Move the projector to a

temperature of 0 ˚C to 45 ˚C
and the humidity of 20 % to
80 % (no condensation).

• Turn off the MAIN POWER

switch using the procedure on
page 23 and clean the air filter
(refer to page 51).

Lighting in

red

(lamp unit

ON)

Remedial measure

Blinking in

red

(1 time)

Blinking in

red

(2 times)

The filter is clogged.

High temperature
inside
(Standby condition)

Blinking in

red

(3 times)

Cooling fan has
been stopped.

• Turn off the main power supply

(MAIN POWER) switch in the
procedure shown on page 23
and consult the distributor.

• This lamp monitor lights up

when the lamp unit used hours
have reached 2 800 hours.

• Wait until the lamp has cooled

off, and then turn on the
power.

• Did you notice a

“REPLACE THE LAMP”
message on the screen
when turning on the
projector power supply?

• Are lamp units

installed correctly?

• Did you turn the power

back on immediately
after turning it off?

• Turn off the MAIN POWER

switch using the procedure on
page 23 and consult the
dealer.

• Some error has

arisen in the lamp
circuit.

• Check for fluctuation

(or drop) in the source
voltage.

Indicates the time
for replacing the
lamp unit.

Error is detected in
the lamp or lamp
power.

Lighting in

red

Blinking in

red

(3 times)

Temperature

monitor

TEMP

Lamp monitor

LAMP1 LAMP2

Advertising