Installation—gas connections, Warning, Provide adequate gas supply – GE JGP630 Manuel d'utilisation

Page 6: 1install regulator, Install regulator onto burner box bottom, 3complete connection with a coupling

Advertising
background image

6

Installation Instructions

INSTALLATION—GAS CONNECTIONS

PROVIDE ADEQUATE
GAS SUPPLY

This cooktop is designed to operate on
natural gas at 4

″ of water column manifold

pressure and 7

″ of water column (W.C.)

supply pressure. It is shipped from the
factory set for natural gas. The convertible
pressure regulator supplied with the unit
must be connected in series with the
manifold of the cooktop and must remain in
series with the supply line regardless of
whether natural or L.P. gas is being used.
FOR PROPER OPERATION, THE MAXIMUM
INLET PRESSURE TO THE REGULATOR
MUST BE NO MORE THAN 14

″ OF WATER

COLUMN PRESSURE. For checking the
regulator, the inlet pressure must be at least
1

″ W.C.. (or 3.4 KPA) greater than the

regulator output setting. If the regulator is set
for 4

″ W.C. of water column pressure, the

inlet pressure must be at least 5

″ W.C. If the

regulator is set for 10

″ W.C., the inlet pressure

must be at least 11

″ W.C.. The gas supply line

to the cooktop should be 1/2

″ or 3/4″ pipe.

1

INSTALL REGULATOR

NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.

WARNING:

Never reuse old

flexible connectors. The use of old flexible
connectors can cause gas leaks and personal
injury. Always use new flexible connectors
when installing a gas appliance.

To reduce the likelihood of gas leaks, apply
teflon tape or a thread compound approved
for use with LP or Natural gases to all
threaded connections.

2

Screw a section of pipe
onto the inlet end of the
pressure regulator and
install the coupling.

INSTALL REGULATOR ONTO
BURNER BOX BOTTOM

Screw the
regulator onto
the burner box
bottom pipe
connection.
Make sure the
top of the
regulator is
facing towards the
cabinet front,
easily accessible
through the
cabinet doors.

3

COMPLETE CONNECTION
WITH A COUPLING

Complete the
connection
between the
regulator pipe
coupling and
the shut-off valve.

4

Pressure

Regulator

Pressure

Regulator

Shut-Off

Valve

Coupling

Electrical

Outlet 12

Below

Countertop

Coupling

Pressure

Regulator

Shut-Off

Valve

Coupling

Electrical

Outlet 12

Below

Countertop

Advertising