Maintenance and Cleaning

Be sure to reset the Lamp replacement counter after the lamp is replaced. When the Lamp replacement
counter is reset, the LAMP REPLACE indicator stops lighting.

Turn the projector on, press the MENU button to
display the On-Screen Menu. Press the Point

7 8

buttons to move the red framed pointer to the Setting
Menu icon.

Press the Point

ed

buttons to move the red framed

pointer to the Lamp counter function and then press
the SELECT button. The first dialog box appears and
shows the total accumulated time of the lamp usage
and the reset option. If you select "Reset", a "Lamp
replacement counter Reset?" message will appear.
Select [Yes] to continue.

1

2

Another confirmation dialog box will appear, select
[Yes] to reset the Lamp replacement counter.

3

This projector uses a high-pressure lamp which must be handled carefully and properly.
Improper handling may result in accidents, injury, or create a fire hazard.

Lamp life may differ from lamp to lamp and according to the environment of use. There is no

guarantee of the same life for each lamp. Some lamps may fail or terminate their life in a shorter
period of time than other similar lamps.

If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights

up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down.
( Follow carefully the instructions in the Lamp Replacement section of this manual. ) Continuous use
of the lamp with the LAMP REPLACE indicator lighted may increase the risk of lamp explosion.

A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its

lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in
which the projector and lamp are being used.

IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.

If a lamp explodes, disconnect the projector’s AC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check
carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out
from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one
should check the inside of the projector except those who are authorized trained technicians and who are
familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those
who are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken
glass.

LAMP HANDLING PRECAUTIONS

Lamp Replacement Counter

Note:

Do not reset the Lamp replacement counter without implementation
of lamp replacement. Be sure to reset the Lamp replacement
counter only after replacing the lamp.

Select [Yes],
then another
confirmation box
will appear.

Select [Yes] again
to reset the lamp counter.

To reset the lamp counter,
move the pointer to Reset
and then press the SELECT
button.
“Lamp replacement
counter Reset?” dialog box
will be displayed.

Maintenance & Cleaning